omron — Point Finder

Point Finder Location Properties for the Region of Interest Related Topics Point Finder Configuring Point Finder Properties - Advanced Configuring Point Finder Properties - Advanced The Advanced Properties section of the Point Finder tool interface provides access to advanced Point Finder parameters and properties. Connectivity Connectivity is the minimum number of connected edges required to generate a point hypo- thesis. By default, Connectivity is disabled. When enabled, you can set the minimum number of con- nected edges that are required to generate a point hypothesis. Contrast Threshold Mode Contrast Threshold defines how contrast threshold is set.

Contrast threshold is the level of sensitivity that is applied to the detection of edges in the input image. This threshold is expressed in terms of a step in grey-level values. The contrast threshold can be either Adapt- ive or Fixed. ACEUser's Guide, 3.6.x, 18316-000 Rev A Page 596 Height Height of the region of interest Width Width of the region of interest