Remote Vision Tool Remote Vision Configuration Screen 2. In the Port Number field, enter the port number of the Remote Vision Server. 3. In the Vision Server IP Address field, enter IP address of the Remote Vision Server. The Remote Tool Name list will be populated with the ACE Sight vision tools available on the Remote Vision Server. 4. In the Time Out field, specify a time out, in milliseconds. This is the maximum time to wait for the remote tool to complete its processing. 5. In the Remote Tool Name field, select the vision tool to run on the remote PC. The field will be populated with the available tools on the server. 6. Run the Remote Vision tool (click Run).
The results of the remotely-run vision tool will be transmitted from the Remote Vision Server to the ACE PC when that tool is run, through the Remote Vision tool. ACEUser's Guide, 3.6.x, 18316-000 Rev A Page 605