ACE Sight Latch Calibration ACE Sight Belt Calibration Wizard ACE Sight Camera Calibration Interview Wizard ACE Sight Camera Calibration Wizard - Automated, no Belt ACE Sight Camera Calibration Wizard - Automated, w/ Belt ACE Sight Camera Calibration Wizard - Manual w/Belt ACE Sight Camera Calibration Wizard - Automated, Arm-Mount ACE Sight Camera Calibration Wizard - Manual, Arm-Mount ACE Sight Latch Calibration ACE Sight Latch Calibration calibrates a robot to a latch. This calibration uses a user-supplied sensor to generate a latch signal when an object, such as a pallet, reaches a specific point, typically on a conveyor belt.
This synchronizes the rest of the system with the position of the object. This calibration is available in Emulation Mode. The end result of this calibration is an ACE Sight Latch Calibration object. Requirements l The PC running the ACE Sight software must be connected to the controller for the robot. l A belt calibration must exist in the Workspace. l The robot, controller, and belt must be correctly connected and functioning. l The signal to be used for the latch must be set in the SmartController. This is covered in the following section. NOTE : In Emulation Mode, you will not be asked for a latch signal number, as this is not needed. You can then skip the following section.
To set the latch signal in the SmartController: 1. Double-click the SmartController object in the Tree structure to open the object editor. 2. Click Configure. 3. Check the Configure Encoder Latches. ACEUser's Guide, 3.6.x, 18316-000 Rev A Page 742