Process Strategies For more details on creating or using a custom V+ program, see Custom V+ Programs on page 937. Robot Parameters The Robot Parameters are displayed when the robot is selected in the Process Strategy Editor. There are four groups of robot parameters: the General Parameters group, the Allocation group, the Wait Mode Parameters group, and the Error Response group. The General Parameters group is used to specify the queue size and pick rate filter for the selected robot; the Wait Mode Parameters group is used to specify the "wait" settings (used when there are no parts or tar- gets to process). Robot Parameters For this screen, the parameters are:
ACE User's Guide, 3.6.x, 18316-000 Rev A Page 881 Item Description Use Custom Belt Pro- gram The default belt program monitors the speed/on/off status of all belts. You can copy the default V+ belt program for editing, or select an existing pro- gram. Use Custom Error Program The default error program handles the processing and reporting of robot errors during the execution of a process. You can copy the default V+ error program for editing, or select an existing program. Use Custom Stop Program The custom stop program can be used to perform certain operations after the application has stopped. You can copy the default V+ stop program for edit- ing, or select an existing program.