omron — AutoVISION Quick Start Guide

AutoVISION Quick Start Guide December 2020 Precautions for Correct Use Direction of adjust parameters a. To reduce inspection time Adjust [Allowed Rotation] as small as possible Ex.) If the work will not rotate, set from +\-180(Default) to 10 degree or less. Just enough for normal rotation. b. To optimize location of the target model i. Prevent the algorithm from choosing the incorrect edges by setting [Fit Quality] to [Precise] ii. To allow the algorithm to find parts that may have variance in edge locations, set [Fit Quality] to [Relaxed or Manual] (*). You may also lower the Accept Threshold percentage. (*)[Accept Threshold] and [Conformity Tolerance] are automatically set.

If part is being located correctly, click [Show Advanced Parameters Window] and adjust other parameters. To check the detail, see HELP.