omron — AutoVISION Quick Start Guide

AutoVISION Quick Start Guide December 2020 c. Change the Presence tool settings to pass when the gasket tab is present in the tool. The orange pixels inside the tool are the pixels that are counted. i. Adjust the Upper/Lower Threshold, using the sliders, to make the gasket tab appear orange. ii. Set the [Tolerance] so that the Presence tool will pass when a gasket tab is in the tool but fails when the tool contains all light or dark pixels. Note the pixel count in the [Presence1] tool on the left side of the screen. The lower and upper tolerance settings should bracket this value to determine if the tab is present. iii. Enable the Rotate option. d.

Click [Zoom to Fit] to see the entire image ciii d ci cii