Installation instructions en 6. Undo the internal setting screw. Replacing grill burner nozzles on appliances with a grill burner 1. Undo the screws on the front holder and pull the burner forwards and out of the gas connection. 7. Fit the control knob and heat up the oven for 15 minutes. 8. Turn the controller to the minimum position. 9. Remove the control knob. 10. Adjust the internal adjustment screw until a stable On the back wall, the burner is still connected to the gas supply and the electric ignition. 2. Carefully place the burner with its front side on the flame is burning correctly. If required, loosen the adjustment screw to increase the gas flow.
Tighten the adjustment screw to re- duce the gas flow. The setting is correct when the height of the small flame is approx. 3 to 4 mm. Tighten the adjustment screw in the case of a liquid connection. 11. Attach the control knob. 12. Ensure that the flame does not go out if you quickly base of the cooking compartment. 3. Unscrew the nozzle and replace it with a nozzle that is suitable for the new gas type. → "General nozzle table", Page 25 change the gas flow from maximum to minimum and vice versa, and if you open and close the appli- ance door. 4. Replace the label for the gas type with the new label that is included with the nozzle set. 5.
To install the burner carry out the instructions in re- verse order. General nozzle table Gas type/burner mbar Nozzle number Bypass Power in watts Minimum power in watts Maximum consump- tion Natural gas G20/oven burner 20 135 (H1) Gap 3600 1200 G20: 352 l/h Natural gas G20/grill burner 20 130 (H3) 3000 G20: 298 l/h Liquid gas butane/propane G30/ G31/oven burner 90 (H1) 58 3600 1200 G30: 269 g/h G31: 264 g/h Liquid gas butane/propane G30/ G31/grill burner 28 - 30/37 28 - 30/37 83 (S) 3000 G30: 218 g/h G31: 214 g/h Nominal operating pressure Your appliance's nominal operating pressure is:
Ў For natural gas – NG (G20) 20 mbar/2.0 kPa Ў For liquid gas – LPG (G30) 30 mbar/3.0 kPa Ў For liquid gas – LPG (G31) 37 mbar/3.7 kPa shall accept no liability for the functionality and power of your appliance or for other risks id you operate your appliance with pressure values that differ from those specified for your appliance. Note: If you are operating your appliance with liquid gas, use a gas pressure regulator. The pressure regu- lator must be connected and maintained by a licensed expert. You must operate your appliance with these pressure values. All information on your appliance's rating plate relates to these pressure values. The manufacturer 25