ELECTRICAL AND ECU Repair 12/05 Replace Charge Air Pressure Sensor Replace Charge Air Temperature Sensor 1. Disconnect battery negative (-) cable. 2. Disconnect electrical connector (Figure 12-25, (1)) . 1. Disconnect battery negative (-) cable. 2. Disconnect electrical connector (Figure 12-27, (1)) . Figure 12-25 Figure 12-27 (1) (1) Figure 12-25 Figure 12-27 3. Pull sensor out of charge air pipe. 4. Install new sealing ring (Figure 12-26, (1)) before installing sensor (Figure 12-26, (2)) . 3. Remove sensor from charge air pipe. 4. Replace sealing ring before installing sensor. Figure 12-26 5. Install sensor and tighten to 7 N·m (62 in.-lb.). Connect electrical connector. 6.
Connect battery negative (-) cable. 7. Check and delete any trouble codes that are registered in the ECU after the work has been completed. Figure 12-26 5. Install sensor and connect electrical connector. 6. Connect battery negative (-) cable. 7. Check and delete any trouble codes that are registered in the ECU after the work has been completed. © 2009 Yanmar Marine International BY Service Manual 12-23