MAN Nutzfahrzeuge Aktiengesellschaft — Drive stage selection

Test Drive stage selection Flash code: 1x short Fault indication: Fault is indicated by the EDC indicator lamp coming on continuously Fault path: Drive stage selection Signal too high Signal too low Signal implausible with idle speed switch Effect of fault: Engine assumes lower idle speed Possible cause: Line break, short-circuit, power supply interrupted, drive stage selection defec- tive, control unit defective Test precondition: Socket box connected “Ignition” switched on 31 Test Measurement Corrective measures Voltage supply Measure voltage at the socket box across pin 45 (+) and pin 13 (–) Setpoint:

4.75–5.25 V – Check lines – Check plug connections – If no fault found, replace control unit (disconnect the control unit only when the current is switched off) Drive stage selection PWG Min. 0 % PWG Max. 100 % Measure voltage at the socket box across pin 27 (+) and pin 13 (–) Setpoints: Idle speed setting: 0.3–0.5 V Full load setting: 2.9–3.1 V – Check lines – Check plug connections – Replace drive stage selection Idle speed switch PWG Min. 0 % PWG Max. 100 % Measure voltage on the socket box across pin 39 (+) and pin 13 (–) Setpoints: Idle speed setting: 4.75–5.25 V Full load setting: 0.0–2.0 V – Check lines – Check plug connections Switch open Switch closed