Operation 3.3 Operation Check air cleaner element ! If inspection, cleaning, or maintenance is carried out with the engine running, dirt will get into the engine and damage it. Always stop the engine before carrying out these operations. ! When using compressed air, there is danger that dirt may be blown around and cause serious injury. ! Always use protective glasses, dust mask, and other protec- tive equipment. 1. Open the engine side cover on the right side of the chassis. 1 2. If the yellow piston in the display portion of dust indicator (1) installed to the air cleaner enters the red range (7.5 kPa), clean the element. 3.
After cleaning, press the button of the dust indicator to reset it. 4. If the yellow piston enters the red range (7.5 kPa) soon after the dust indicator is reset, it is necessary to replace the ele- ment. For details, see "Replacing element (4-34)". GK038073 Electric air cleaner clogging sensor (Machines equipped with KOMTRAX) If the yellow piston in the display portion of dust indicator (1) enters the red range (7.5 kPa), or air cleaner clogging caution lamp (2) on the machine monitor lights up, clean the air cleaner element. NOTE ! Do not clean at the element until the air cleaner clogging caution lamp lights up. !
If the element is cleaned frequently before the air cleaner becomes clogged, the air cleaner will not be able to provide its expected performance and the cleaning efficiency will become poor. GK038005 2 ! In addition, dirt stuck to the element will drop inside the inner element more frequently during the cleaning operation. WA380-6H – VEAM440100 3-89 WARNING WARNING