Komatsu — Removal and installation of battery

3.7 Troubleshooting Operation Removal and installation of battery 1. Before removing battery, remove the ground cable (normally connected to the negetive (-) terminal). If any tool touches between the positive terminal and the chassis, there is dan- ger of sparks being generated. Loosen the nuts of terminal and remove the wires from the battery. 2. After installing the battery, fix it with the battery fitting securely. Tightening torque: 2 to 2.9 Nm 3. When installing the battery, connect the ground cable last. Insert the hole of the terminal on the battery and tighten the nut. REMARK Tightening torque: 5.9 to 9.8 Nm The batteries are on both sides at the rear of the machine.

The battery used for the ground is on the left side of the machine. 3-160 WA380-6H – VEAM440100