Komatsu — Clean axle case breather

4.9 Service procedure Maintenance When required Clean axle case breather When cleaning the axle breather, apply the parking brake and secure the front and rear frames with the safety bar. ! A: Front ! B: Rear Remove all mud and dirt from around the breather with a brush. After removing the mud or dirt from around the breather, remove the breather, immerse it in cleaning fluid and clean it. When cleaning the breather, clean the breathers at two places (front and rear). After removing the breather, take steps to prevent dirt or dust from entering the mount. WA380-6H – VEAM440100 4-41 WARNING WARNING A GK043063 GK043063 B GK043064 GK043064