Komatsu — Replace slow blow fuse

4.9 Service procedure Maintenance When required Maintenance and inspection and time to execute them Replace slow blow fuse A B ! Always turn the power OFF when replacing the slow blow fuse (turn the starting switch to the OFF position (A)). NOTE ! Always replace the slow blow fuse with a fuse of the same capacity. C 1. Turn the starting switch to the OFF position (A). 2. Remove the slow blow fuse box from the chassis. GK038021 3. Open covers (1), (2), and (3) of the slow blow fuse box. Covers (2) and (3) can be removed easily by using protru- sion (A) on the body as a fulcrum and levering the catch of the cover with a flat-headed screwdriver to release it. 5 8 6 2 4.

Loosen screws (4) and (5), and remove. When screws (4) and (5) are removed, slow blow fuse (6) will also come off together with electric wiring (7) and (8). 5. Using screws (4) and (5), install a new slow blow fuse together with electric wiring 7 and 8 to the slow blow fuse box, then close covers (1), (2), and (3). 1 A 4 7 3 6. Install the slow blow fuse box to the chassis.

GK032262 WA380-6H – VEAM440100 4-51 Inspection location Item to check for Maintenance interval Check before 6 mon operating Replacement ths interval Filter Clogging, dirt Carry out check - 2 years Condenser Clogging, dirt Carry out check - - Belt Looseness, damage Carry out check - 2 years Refrigerant gas Amount - Carry out check - Piping Looseness, damage, leakage - Carry out check - Receiver drier - - - 2 years