Komatsu — 6.2.2 Method of operation

6.2 Handling torque converter lock-up Attachments, Options 6.2.2 Method of operation 1. Press the top (a) of the torque converter lock-up switch to turn it ON. a The pilot lamp inside the switch lights up. 2. When the actual speed range is 3rd or 4th in either FOR- WARD or REVERSE, the torque converter lock-up function is actuated according to the travel speed and sets to direct drive. b REMARK When the gearshift lever is at 4th in auto-shift mode, the lock-up is not actuated if the actual speed range is 3rd. The lock-up is actuated only when the actual speed range is 4th. GK038038 When the lock-up is actually actuated, the lock-up pilot lamp on the machine monitor lights up. 3.

To cancel the lock-up, press the bottom (b) of the torque converter lock-up switch to turn it OFF. The lock-up is canceled. The travel speed for actuation and cancellation of the lock-up is as shown below. GK050035 6-6 WA380-6H – VEAM440100 Lock-up Speed range FORWARD travel speed (km/h) REVERSE travel speed (km/h) Actuated Canceled Actuated Canceled 3rd 13 to 15 {12 to 14} 13 to 14 {12 to 13} 14 to 16 {13 to 15} 14 to 15 {13 to 14} 4th 22 to 25 {20 to 23} 21 {19} 23 to 27 {21 to 25} 23 {21}