DRESSTA Co. Ltd. TD-25H — 5.8.6.2. FILLING THE DRAINED SYSTEM

MAINTENANCE SECTION 5 Page 23 COOLING SYSTEM Check the coolant level daily to be sure that the level is proper. For checking coolant level place the machine on the level ground and lower the mounted equipment to the ground. Coolant level must be seen in the sight gauge. If coolant has to be added check and replenish DCA-4. 5.8.6. CHANGING COOLANT 5.8.6.1. Draining the System (Fig. 5.7) 1. Position the machine on level ground. 2. Run the engine until it reaches the temperature of 50 [єC] then stop the engine. 3. Remove the radiator cap. Refer to “RADIATOR CAP”. 4. Open radiator drain valve (1) located in the radiator lower tank on the right hand side of the machine.

Access to the valve is gained after the removal of the front bottom guard. 5. Open engine drain cock (2) on the cylinder block. 6. Open oil cooler drain cock (3) located on the bottom of the oil cooler. 7. Open the shutoff valve at the cooling filter head. 8. Allow the system to drain completely; do not let drain outlets plug up from foreign material. 9. Change coolant filter. Install a filter of greater capacity. (Procedure is shown in Engine Operation Manual). Fig. 5.7. Water Coolant Drain Valves. 1. Radiator Drain Valve 2. Engine Draincock on the Cylinder Block 3. Oil Cooler Draincock 5.8.6.2. FILLING THE DRAINED SYSTEM IMPORTANT: Do not fill a cooling system with water alone.

Use antifreeze and water solution in proportions as specified in "REFILL SPECIFICATIONS AND CAPACITIES CHART" according to the ambient temperature. 1. Close the radiator drain valve, the engine oil cooler draincock, the draincock on the cylinder block and the coolant filter shutoff valve. DRESSTA TD-25H