SECTION 5 MAINTENANCE Page 30 ENGINE Fig. 5.14. Engine Oil Filler 5. Fill the crankcase with fresh oil (Fig. 5.14). Refer to the "REFILL SPECIFICATION AND CAPACITIES CHART". 6. Check the oil level with the oil dipstick as described in 5.11.1. IMPORTANT: After the oil has been replaced, start the engine according to the instructions specified in Section 4 "ENGINE START AFTER OIL CHANGE OR PROLONGED STANDSTILL". 5.11.3. ETHER INJECTOR (if equipped) Precautions WARNING! Ether starting fluid is highly flammable. Explosion can result if sparks or flame contact ether or a container is stored in temperature above 70 [°C]. Follow the precautions on the container. Observe the following precautions:
Do not use the ether injector when air temperature is above 0 [°C]. Do not use open flame when using ether starting fluid. Do not store fluid containers in the operator's compartment. Store containers in a cool, well ventilated place. Keep fluid containers out of reach of unauthorized personnel. Do not breathe hazardous ether vapor. Do not let ether contact your skin, because it can cause frostbite. Never puncture a fluid container or put it into fire. Dispose of empty containers properly. For your safety, remove the ether container when welding, grinding, or using a torch on a machine. Follow the correct method of starting the engine. Refer to "STARTING THE ENGINE" in this manual.
TD-25H DRESSTA