DRESSTA Co. Ltd. TD-25H — 4.6.2. ETHER INJECTION START

OPERATING SECTION 4 Page 19 STARTING THE ENGINE 6. Sound horn (5) to clear all personnel of the immediate area. 7. Crank the engine with button (6). IMPORTANT: Do not crank an engine for more than 30 seconds at a time. If the engine does not start, allow the cranking motor to cool two or three minutes before cranking again. 8. Check the oil pressure. Stop the engine immediately, if the gauge fails to show the correct pressure after 15 seconds. 9. Allow the engine to idle for 3 to 5 minutes (app.1000 [RPM]) before increasing engine speed and placing under load. 10. Check the indications of all instruments to ensure that the machine is operating correctly Refer to “INSTRUMENT PANEL”.

IMPORTANT: It is not recommended to run the engine at low idle over 10 minutes due to a possibility of increased wear of engine components. 4.6.2. ETHER INJECTOR START (temperatures below 0 [°C]) (Fig. 4.13). WARNING! Ether starting fluid is highly flammable. Follow the precautions on the container. An explosion can result if sparks or flame contact ether or when storing an ether container when the air temperature is above 70 [°C]. Observe the following precautions: Do not use the ether injector when the air temperature is above 0 [°C]. Do not use open flame when using ether starting fluid. Do not store fluid containers in the operator's compartment.

Store containers in a cool, well ventilated place. Keep fluid containers out reach of children. Do not breathe hazardous ether vapor. Do not let ether contact your skin, because it can cause frostbite. Never puncture a fluid container or put it into a fire. Dispose of an empty container per instructions printed on the container. For your safety, remove the ether container when welding, grinding, or using a torch on a machine. Follow the correct method for starting the engine. Before any attempt to start the engine, check the ether container or insure that a supply of starting fluid is available under pressure and the system is in working condition.

Pressing the switch in the instrument panel makes ether injection. IMPORTANT: The ether injector is to be used for engine starting only. Misuse of the ether injector while the engine is running can result in a serious damage to the engine. 1. Perform all steps as described in items 1 through 6. Refer to “NORMAL START” (temperature above 0 [°C]). 2. Press the starting button (6) and during engine cranking press the ether injector switch. Allow one to two seconds for the chamber in the valve to fill then, with the engine cranking, release the ether injector switch to release a measured shot of starting fluid into the engine. DRESSTA TD-25H