puls — Puls 1106 Series Marine Propulsion Engines Installation Manual

N40475 Chapter 8 Cables required Where Used: Connects the PCP and MMPD displays into the J1939 data link. The J1939 data link (item 1 figure 15) can not exceed 40 meters (131ft.). Requires: MMPD drop cable Tee to Tee cable 6-pin Tee Termination resistor Figure 15 Termination resistor (figure 16) Used to terminate the ends of a data link run. Two termination resistors required Tee connector (figure 17) Used to connect tee to tee cables. CAN Data Link SAE J1939-15: Unshielded twisted pair. The CAN network operates at 250 Kb/sec, it follows J1939-15 protocol.

J1939-15 Figure 16 Maximum Drops (nodes) 10 Maximum Cable Stub Length 3M Maximum Cable Stub Length for service connector 2.66M Maximum Bus Length 40M Shielded Cable NO Figure 17 Page 35