puls — Puls 1106 Series Marine Propulsion Engines Installation Manual

Chapter 8 N40475 Diagnostic lamp (Pin 2) The diagnostic lamp, figure 27 alerts the operator to the presence of an active diagnostic code. A diagnostic code indicates a fault condition in the electronic control system. The operator uses this indication to help diagnose component failures in the electronic control system. The diagnostic flash codes should only be used to indicate the nature of the occurrence of a diagnostic condition. The flash codes should not be used to perform detailed troubleshooting. Troubleshooting should be performed using diagnostic codes that are displayed by using an electronic service tool.

Figure 27 When the ECM is energized (keyswitch turned ON), the warning lamp will turn on for five seconds. Then the lamp will turn off unless the ECM detects a warning condition. 1. Diagnostic lamp. Figure 28 2. + Battery bus bar. Warning lamp (Pin 1) The warning lamp figure 28 is used to alert the operator that an engine event has occurred. A warning event code is active; the warning lamp is on solid. A derate event code is active; the warning lamp will flash. When the ECM is energized (keyswitch turned ON), the warning lamp will turn on for five seconds. Then the lamp will turn off unless the ECM detects a warning condition. 1. Warning lamp 2. + Battery bus bar.

- Battery (Pin 11) The minus battery input from the minus battery bus bar Keyswitch (Pin 12). The switched battery input from the keyswitch, used to supply +battery to the components connected to the custom panel connector . Maintenance Clear switch (Pin 16) The maintenance clear switch is required to reset the PM1 interval after maintenance has been performed on the engine. Page 42