TM 5-3805-280-10 Operational Checkout 2 OPERATOR STATION CHECKS—ENGINE ON –1/1 21-4 MONITOR CIRCUIT, GAUGE CHECKS Start engine. Are all monitor indicator lights OFF after engine starts? Is coolant temperature gauge needle (A) in normal operating zone after a few minutes? Does fuel gauge (B) indicate fuel level? Stop engine. T107698 –UN–27FEB97 YES: Go to next check. NO: Check alternator belt if battery light is on after engine starts. Go to your authorized dealer. – – –1/1 POWER MODE CIRCUIT CHECKS Start engine. Auto-idle switch OFF. Propel speed switch in fast position. Pilot shut-off lever in LOCKED position. Push power mode select switches (A) and (B) one at a time.
Do corresponding indicator lights come on as each switch is pushed? T102098 –UN–26JUL96 YES: Go to next check. NO: Check controller fuse. Go to your authorized dealer. – – –1/1