TM 5-3805-280-10 OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES FOR HYDRAULIC EXCAVATOR 230LCR/230LCRD A-15 ITEM NO. INTERVAL ITEM TO BE INSPECTED PROCEDURE: DO THE PMCS AND HAVE ITEM REPAIRED, FILLED, OR ADJUSTED AS NEEDED EQUIPMENT IS NOT READY/AVAILABLE IF: CAUTION: Prevent possible damage to engine. If indicator lights do not go out after starting engine, IMMEDIATELY STOP THE ENGINE. Find and correct the problem. (4) Check that all indicator lights go out. (5) Check hydraulic oil level. a. Park machine on level surface. b. Position machine with arm cylinder fully retracted, bucket cylinder fully extended, and bucket lowered to the ground.
(Reference placard located to the left of the hydraulic sight gauge.) c. Turn auto-idle switch off. d. Run engine with engine rpm dial at 1/3 position without load for 2 minutes. e. Move engine rpm dial to slow idle position. f. Turn key switch OFF and remove key. g. Attach a “Do Not Operate” tag on the right control lever. h. Pull pilot control shut-off lever to locked position. i. Open right side access door. One or more indicator lig do not go out after startin engine