Komatsu — eebm001902 a3.pdf

STRUCTURE AND FUNCTION CLSS Operation Pilot pressure PA of pump merge-divider valve (5A) ON. 1. Bucket group a. When the bucket is operated, pressurized oil from main pump (2B) flows to the bucket group. The swash plate angle of main pump (2B) is controlled to match the operation of bucket spool (6). b. The LS pressure passing through the inside of bucket spool (6) goes to unload spool (28A), and the unload valve is closed. 2. Arm group a. When the pump flow is divided, all spools are at neutral, so the oil flow from the minimum swash plate angle of main pump (2A) is all drained from unload valve (28B) of the arm group.

All spools in the arm group are at neutral, so no LS pressure is generated. b. If the pump pressure - LS pressure becomes greater than the set pressure of unload valve (28B), the unload valve is actuated and the oil is drained. The LS differential pressure L PLS at this point is L PLS > pump LS control pressure, so the pump swash plate angle is the minimum. 10-77