Komatsu — eebm001902 a3.pdf

STRUCTURE AND FUNCTION TRAVEL MOTOR 2. Motor swash plate angle (capacity) at minimum (Hi speed) a. When the solenoid valve is excited, the pilot pressure oil from the main pump flows the port P , and pushes regulator valve (9) to the left in the direction of the arrow b. Because of this, the main pressure oil from the control valve passes through passage d in regulator valve (9), enters regulator piston (15) at the bottom, and pushes regulator piston (15) to the right in the direction of the arrow. c. As a result, swash plate (4) moves in the minimum swash plate angle direction, the motor capacity be- comes minimum. 10-100