Komatsu — eebm001902 a3.pdf

STRUCTURE AND FUNCTION TRAVEL MOTOR c. Operation of brake when traveling downhill i. If the machine tries the run away when traveling downhill, the motor will turn under no load, so the pressure at the motor inlet port will drop, and the pressure in chamber S1 through ori- fices E1 and E2 will also drop. When the pressure in chamber S1 drops be- low the spool switching pressure, spool (19) is returned tot the left in the direction of the arrow by spring (20), and outlet port MB is throttled. As a result, the pressure at the outlet port side rises, resistance is generated to the rotation of the motor, and this pre- vents the machine from running away.

In other words, the spool moves the a position where the pressure at outlet port MB balances the pressure at the inlet port and the force generated by the weight of the machine. It throttles the outlet port circuit and controls the travel speed according to the amount of oil discharged from the pump. 2. Safety valve a. Function i. When travel is stopped (or when trav- elling downhill), the circuits at the inlet and outlet ports of the motor are closed by the counterbalance valve, but the motor is rotated by inertia, so the pressure at the outlet port of the motor will become abnormally high and damage the motor or piping.

The safety valve acts the release this ab- normal pressure and send it to the in- let port side of the motor the prevent damage to the equipment. b. Operation when travel is stopped (or when traveling downhill, rotating to the right) i. When the motor inlet port pressure (pressure PA ) goes down, the pres- sure in chamber S1 also goes down. When it goes below the switching pressure of the spool, spool (19) is re- turned to the left by spring (20), and outlet port passage B1 is throttled. When this happens, the motor contin- ues the rotate under inertia, so the outlet pressure (pressure MB ) rises. 10-104