Komatsu — eebm001902 a3.pdf

ELECTRONIC CONTROL SYSTEM STRUCTURE AND FUNCTION Function There are five modes available for selection with the working mode switch on the monitor panel. These modes are the heavy-duty opera- tion (H/O) mode, general operation (G/O) mode, finishing operation (F/O) mode, lifting operating (L/O) mode, and the breaker opera- tion (B/O) mode. It is possible to select the most suitable engine torque and pump absorption torque to match the nature of the work.

The engine throttle • pump controller detects the actual engine speed and the speed set by the engine governor through the fuel control dial in accordance with the pump absorption torque set for each mode, and carries out con- trol so that the pump absorbs all of the torque at each output point of the engine. 10-141