Komatsu — eebm001902 a3.pdf

STRUCTURE AND FUNCTION ELECTRONIC CONTROL SYSTEM Power maximizing • Swift slow-down function Function lifting operation (L/O) and reduces the speed. It is operated using the L.H. knob switch to momentarily match the operating conditions. The power max. function and the swift slow-down function are operated with the same switch. Only one of these functions can be selected at any time; they cannot both be operated together. Power maximizing function During digging operations, when that extra bit of digging power is needed (for example, when digging up boulders), the L.H. knob switch can be pressed to raise the hydraulic pressure by approximately 10% and increase the digging force. If the L.H.

knob switch is pressed ON when the working mode is H/O or G/O, each function is automatically set as follows. Swift slow-down function During normal operations, if it is desired to carry out lifting operations or finishing operations for a moment, the working mode can be switched to lifting operation (L/O) mode by operating the L.H. knob switch. If the L.H. knob switch is pressed ON when the working mode is at H/O or G/O, each function is automati- cally set as follows. 10-148 Working mode Engine pump control 2-stage relief function Actuating time Heavy-duty operation Matching at rated output point Actuated 31.9 MPa ¡’ 34.8 MPa (325 ¡’ 355 kg/cm2) Automatically cancelled after 8.5 sec.

Working mode Actuating time Lifting operation While switch is kept pressed