Komatsu — eebm001902 a3.pdf

STRUCTURE AND FUNCTION ELECTRONIC CONTROL SYSTEM Active mode function Function When the active mode switch on the monitor panel is turned ON (lamp lights up), it is possible to increase the speed of the operation by increasing the speed when there is a light load and by detecting the load when there is a heavy load. The active mode is actuated only when the fuel control dial is at the Max. position. If the fuel control dial is not at the Max. position, the load sensing function is actuated but the pump discharge increase function is not actuated. 10-157