Komatsu — eebm001902 a3.pdf

STRUCTURE AND FUNCTION MACHINE MONITOR SYSTEM Display timing, content 1. Oil change display After all the lamps lights up, the elapsed time is displayed for 10 seconds. For the next 10 sec- onds, the telephone number is displayed. How- ever, if no telephone number has been input, the elapsed time is displayed for 20 seconds after all the lamps light up. 2. Elapsed time confirmation After all the lamps light up, the elapsed time is displayed for 10 seconds. Elapsed time reset 1.

During the oil change interval display and the elapsed time display, for 10 seconds after all lamps light up (during the elapsed time display), if the buzzer cancel switch is pressed and held for 3 seconds, the elapsed time is reset. When the elapsed time is reset, the elapsed time shows [0h] for 1 second. 2. When the set time is changed, the elapsed time is reset to [0h]. Demo mode 1. The set time in the demo mode is 250h and the elapsed time is set to 240h. When the key is turned ON, the oil change display is given. However, the elapsed time does not increase. It is also possible to carry out the reset operation during this display.

In the demo mode, after the key is turned ON three times, the interval set- ting is automatically set to [no setting] from the 4th time. In addition, the elapsed time is reset to 0h and the elapsed time count starts. "How to set telephone number" procedure see page 10-169 10-168