Komatsu — eebm001902 a3.pdf

TROUBLESHOOTING DISPLAY METHOD AND SPECIAL FUNCTIONS OF MONITOR PANEL 4. Governor motor adjustment mode This is used when adjusting the linkage between het governor motor and the injection pump. (For details of the procedure, see TESTING AND ADJUSTING.) 5. Time adjustment mode To adjust the time, do as follows. 20-90 Code Content Bit Details (condition when lighted up) 4C Monitor panel input condition 4 (1) (2) (3) (4) (5) (6) Wiper motor normal rotation relay output: When specified voltage is abnormal Wiper motor reverse rotation relay output: When specified voltage is abnormal Window washer motor driver output: When specified voltage is abnormal Operation Display 1.

To set to the governor motor adjust- ment mode, press the time switch + R. H. travel speed switch + R.H. working mode switch. 2. To return to the time display mode use the same procedure as above. 1. 2. Buzzer sounds once a second Operation Display 1. To set to the time adjustment mode, keep the time switch depressed for 2.5 seconds. 2. Use the L.H. working mode switch to advance the hour. 3. Use the R.H. working mode switch to advance the minute. 4. To return to the time display mode use the same procedure as in Step 1. 1. The time mark portion flashes # The example shows the situation when setting to 12:34.