TROUBLESHOOTING DETAILS OF TROUBLESHOOTING AND TROUBLESHOOTING PROCEDURE ii. Check output signals (1) Check LS-EPC solenoid output current (a) Set to the monitoring mode and display monitoring code 15. (b) Run the engine at high idling with all the levers at neutral and in the G/O or H/O mode, and measure the current. # All levers at neutral: 900 ± 80 mA. # Engine at high idling, any lever operated, travel speed at Hi: 0 A. (2) No. 2 throttle signal (a) Set to the monitoring mode and display monitoring code 23. (b) Use the procedure in Step 1.-b. for checking the monitor panel output signal, and measure the engine speed.
(3) Checking ON n OFF solenoid condition (a) Set to the monitoring mode and display monitoring code 23. (b) Refer to Table 3 and check that the applicable bit lights up. Table 3 Types of solenoid and conditions for actuation # Operate the lever slightly and not enough to move the machine. (4) Check PC-EPC solenoid output current (a) Set to the monitoring mode and display monitoring codes13. (b) With the starting switch kept at the ON position (G/O mode), measure the current when the fuel control dial is turned on the MAX position and the auto-deceleration is OFF. Start the engine, (G/O mode) and fuel control dial at MAX (auto-deceleration OFF), current should be 515 ± 100mA. b.
Governor control system i. Check input signal (1) Check fuel control dial input voltage (a) Set to the monitoring mode and display monitoring code 30. (b) Measure the voltage when the fuel control dial is turned from low idling to high idling. (Voltage will decrease.) # Voltage: 0.25 - 4.75 V (2) Check governor potentiometer voltage (a) Set to the monitoring mode and display monitoring code 31. (b) Measure the potentiometer voltage when the fuel control dial is turned from low idling to high idling, then move travel lever slightly. (Voltage will increase.) # Voltage: 0.5 - 4.2 V (Auto-deceleration OFF) ii.
Check output signal (1) Check governor motor drive current (a) Set to the monitoring mode and display monitoring codes 33 and 34. # Code 33 is the A phase and code 34 is the B phase. (b) Measure the governor motor drive current when the fuel control dial is turned in the accelera- tion direction and deceleration direction.
(The current should change, then stabilize within specification.) # Current 700 ± 70 mA 20-99 Nameofsolenoid Actuationcondition Bitthatlightsup Activemode ActivemodeswitchOFF (2) Swingholdingbrake Swingorworkequipmentleveroperated # (3) Pumpmerge/divider Traveloperatedindependently# (4) 2-stagerelief Travelleveroperated# (5) Travelspeedselector TravelspeedselectorswitchHiorMi, engineabove1500rpmandmovetravel leverslightly (6)