TROUBLESHOOTING E-MODE E-7 [E316] Abnormality (step-out) in motor is displayed # This troubleshooting is carried out when there is still an abnormality, so when disconnecting the connector and inserting the T-adapter, or when removing the T-adapter and returning the connector to its original position, if the service code E is not displayed, the problem has been removed. # If any other service code [E306] - [E318] has occurred at the same time, start troubleshooting from the code except code [E316]. # Check that the fuse is normal. # Read the precautions given in TESTING AND ADJUSTING, “Adjusting travel of governor motor lever” before carrying out the troubleshooting.
# Before carrying out troubleshooting, check that all related connectors are properly inserted. # Always connect any disconnected connectors before going on to the next step. ADJUSTING. X02CH016 20-119 YES 1 YES 3 Are E306, E317, and Operate fuel control E318 displayed? YES dial 0 rR MAX and turn starting switch OFF. 4 YES • Turn starting switch Is operation normal? Is there any scuffing ON. 2 • Turn starting switch when spring rod is ON. NO moved to injection Is adjustment of • Turn auto decelera- pump end? NO linkage normal? tion OFF. • Disconnect E05 NO • Disconnect linkage • Turn starting switch at governor motor ON. end. • Turn autodecleration OFF.
NO • Set to governor motor adjustment mode. • See TESTING AND Cause Remedy Go to applicable failure mode Defective engine throttle, pump controller 1) Defective linkage 2) Defective injection pump Defective governor motor Defective governor linkage - Replace Adjust or replace Replace Adjust (For details, see TESTING AND AD- JUSTING)