Komatsu — eebm001902 a3.pdf

TROUBLESHOOTING S-MODE S-6 Engine lacks output (no power) # Check that the monitor panel does not display any abnormality in the governor control system. Measure the engine speed and judge if the cause is in the engine or in the chassis. General causes why engine lacks output Insufficient intake or air Insufficient supply of fuel Improper condition of fuel injection Improper fuel used (if non-specified fuel is used, output drops) Lack of output due to overheating # If there is overheating and insufficient output, carry out troubleshooting for overheating. 20-147