TROUBLESHOOTING C-MODE 20-164 Condition when normal (voltage, current, resistance) Action by controller when abnormality is detected Problem that appears on machine when there is abnormality • Resistance of solenoid: 20 -60 1. The current stops flowing to the sole- noid, so no particular action is taken # If the abnormality is restored by the vibration of the machine, it resets the power source to restore the proper condition. (However, the service code display does not go out). Same content as display for E206 • Between C17 (6) and chassis: Max 1 . Between C17 (5), (7), (13), (14) and chassis: No continuity Detects abnormality in input 1. Retains data when starting switch is ON 1.
Engine stalls, or 2. Work equipment, swing, travel speeds are all slow and there is no power When communications are impossible with the monitor, control is carried out with the following settings: 1. Working mode: G/O 2. Priority mode: OFF 3. Travel speed: Lo 4. Auto-deceleration: ON 5. Power Max: ON (other are as usual) 1. Even when travel is operated, the power max. function does not work 2. The swift speed-down func- tion does not work 3. The auto-deceleration cannot be canceled 4. The travel speed does not increase 5. The priority mode has no effect 6. The automatic mode has no effect • Resistance of solenoid: 7 - 14 1. Makes output to LS-EPC solenoid 0.
# If the abnormality is restored by vibration of the machine, it resets the power source to restore to the proper condition. (However, the service code display does not go out). 1. The Mi and Lo travel speed is too fast 2. In L/O and F/O modes, the work equipment and swing speed is too fast • Current: Approximately 900 mA (Levers at neutral, low idling) 1. The current stops flowing to the LS-EPC solenoid, so no particular action is taken 2. If there is a short circuit with the ground at the (-) end, the current (min 1A) con- tinues to flow to the LS-EPC solenoid. # If the abnormality is restored by the vibration of the machine, it resets the power source to restore to the proper condition.
(However, the service code display does not go out.) 1. In the case of 1, it is the same as E222 2. In the case of 2, electric current (min 1A) continues to flow to the LS-EPC solenoid, so the work equipment, travel, and swing speeds are slow • Between C03 (3) and (16): 0.5 - 4.5 V • Between C03 (6) and (16): 18 -28 V • Between C03 (female) (3) and (16), (3) and chassis • Resistance: No continuity (Disconnect connectors C03 and C08) 1. Takes front pump pressure as 0 MPa (0kg/cm2) when actuating # If the abnormality is restored by the vibration of the machine, it resets the power source to restore to the proper condition. (However, the service code display does not go out).
The travel speed does not auto- matically shift (it does not change from Hi to Lo) # If the button is operated manually, the panel display is switched