TROUBLESHOOTING C-MODE C-2 [E232] Short circuit in pump EPC solenoid system is displayed # This troubleshooting is carried out when there is still an abnormality, so when disconnection the connector and inserting the T-adapter, or when removing the T-adapter and returning the connector to its original position, if an E service code is not displayed, the problem has been removed. # If the starting switch is turned OFF after an abnormality occurs, turn the starting switch ON and check if an E service code is displayed. (If is not displayed, the problem had been removed). # Always turn the pump prolix switch OFF.
# Before carrying out troubleshooting, check that all related connectors are properly inserted. # Always connect any disconnected connectors before going on the next step. Table 1 Table 2 20-172 TroubleshootingNNoo. 21 TroubleshootingNNoo. 23 TroubleshootingNNoo. 43 Resistancevalue BetweenC13(male)(1)-(2) BetweenC02(female)(8)-(18) BetweenC05(female)(3)-(4) 170 -- 1242q BetweenC13(male)(1)-chassis BetweenC02(female)(8)-chassis BetweenC05(female)(3)-chassis Min.1Mq TroubleshootingNNoo. 54 Resistancevalue BetweenC05(male)(1)-(3),(2)-(4) Max.1q BetweenC05(male)(1)(2)(3)(4)-chassis Min.1Mq