Komatsu — eebm001902 a3.pdf

TROUBLESHOOTING C-MODE C-3 [E233] Disconnection in PC-EPC solenoid system is displayed # This troubleshooting is carried out when there is still an abnormality, so when disconnecting the connector and inserting the T-adapter, or when removing the T-adapter and returning the connector to its original position, if an E service code is not displayed, the problem has been removed. If the starting switch is turned OFF after an abnormality occurs, turn the starting switch ON and check is an E service code is displayed. (If it is not displayed, the problem had been removed). # If there is a disconnection in the solenoid or wiring harness, no current flows to the solenoid. If the No.

2 pin of the solenoid is short circuiting with the ground, the current (approximately 1A) continues to flow to the solenoid. # Always turn the pump prolix switch OFF. # Before carrying out troubleshooting, check that all related connectors are properly inserted. # Always connect any disconnected connectors before going on the next step. Table 1 Table 2 20-174 TroubleshootingNNoo. 21 TroubleshootingNNoo. 23 TroubleshootingNNoo. 43 Resistancevalue BetweenC13(male)(1)-(2) BetweenC02(female)(8)-(18) BetweenC05(female)(3)-(4) 170 - -1242q BetweenC13(male)(2)-chassis BetweenC02(female)(18)-chassis BetweenC05(female)(4)-chassis Min.1Mq TroubleshootingNNoo.

54 Resistancevalue BetweenC05(male)(1)-(3),(2)-(4) Max.1q BetweenC05(male)(1)(2)(3)(4)-chassis Min.1Mq