TROUBLESHOOTING H-MODE H-20 Travel speed is slow # Check that the spool of the travel PPC valve is moving the full stroke before carrying out troubleshooting. # Carry out troubleshooting in the H/O mode. # When the swing and work equipment speeds are normal. Note1: Measure the travel speed when operated under no load or the specified time for 20m. (See Standard Value Table for Engine related parts). Measurement of travel motor speed when rotated under no load: Remove the connector of the LS-EPC solenoid, then measure the travel speed when rotated under no load: Remove the connector of the LS- EPC solenoid, then measure the travel speed in Hi and Lo. Note 2:
Output pressure of LS-EPC solenoid: In H/O mode, 0.2 ± 0.2 MPa (2 ± 2 kg/cm 2 ) is output regardless of the engine speed. Note 3: After inspection, do not forget to return the interchanged valves to the original position. 20-229