TROUBLESHOOTING M-CODE M-5 When starting switch is turned ON, none of the lamps on the monitor panel light up for 3 seconds # Check that fuses No. 10 and 13 are not blown. # Before carrying out troubleshooting, check that all the related connectors are properly inserted. # Always connect any disconnected connectors before going on the next step. a) None of lamps on monitor panel light up b) Some of lamps on monitor panel do not light up 20-247 YES 2 YES Is voltage between P01 (9) and chassis normal? 3 YES • Turn starting switch Is voltage between 1 ON. fuse No. 10 and • 20 - 30 V NO chassis normal? Is voltage between P02 (8) (14) - (1) (9) • Turn starting switch NO normal? ON.
• 20 - 30 V • Turn starting switch 4 YES ON. • 20 -30 V Is voltage between fuse No. 13 and NO chassis normal? • Turn starting switch NO ON. • 20 - 30 V Cause Remedy Defective monitor panel Disconnetion, defective contact, short circuit with ground in wiring harness between P01 (female) (9) and fuse No. 10 Disconnection, defeictive contact, short circuit with ground in wiring harness between fuse No. 10 - H05 (2) - M14 (2) (1) - battery relay M Disconnection, defective contact, short circuit with ground in wiring harness between P02 (female) (8) (14) and fuse No. 13 Disconnection, defective contact, short circuit with ground in wiring harness between fuse No.