Komatsu — eebm001902 a3.pdf

TROUBLESHOOTING M-CODE M-11 When starting switch is turned ON (engine stopped), caution items, emergency items flash (battery, engine oil pressure lamps do not light up) # Before carrying out troubleshooting, check that all the related connectors are properly inserted. # Always connect any disconnected connectors before going on the next step. # Check both the alternator system and the engine oil pressure system. a) Alternator system M-11 a) Related electric circuit diagram 20-256 3 YES Does monitoring YES code 43 show a value of greater than 2 100? • Set engine and run NO Is voltage between at mid-range speed YES C03 (female) (12) or above. 1 and chassis normal?

• Set to monitoring Is voltage between code 43 alternator terminal R • Disconnect C03. NO and chassis normal? • Turn starting switch ON. • Max. 1V • Disconnect terminal R. NO • Turn starting switch ON. • Max. 1V Cause Remedy Defective engine throttle - pump controller Defective monitor panel Short circuit with power source in wiring harness between C03 (female) (12) - E08 (2) - alternator R Defective alternator Replace Replace Repair or replace Replace