TROUBLESHOOTING M-CODE M-28 Defective hydraulic oil level sensor system # Remove the hydraulic oil level sensor when carrying out troubleshooting. Table Note 1: Variations in hydraulic oil level. The hydraulic oil level may change according to the angle of the ma- chine, or the swaying of the machine, so if there is any display, check the hydraulic oil level again with the machine at a horizontal place. Note 2: If the problem occurs again, the connector (female) at the chassis end is probably defective, so check the connector and wiring harness at the chassis end. Note 3: Check for vibration at the connector mount. If there is excessive vibration, take the appropriate action. Note 4:
Defective installation is a possible cause, so be careful when installing. If the problem occurs again, check for any vibration of the mount, and if there is excessive vibration, take the appropriate action. 20-273 YES 2 Is any foreign YES material (dirt) stuck to moving part of 3 YES float? Is there any large 1 crack, chip, or NO damage to float? When float is moved up and down, is resis- tance between connec- NO tor (1) and flange as shown in Table 1? 4 YES Check wiring harness visually. Is it broken?
NO NO Cause Remedy Defective movement of float due to dirt Resonance of mount (See Note 2) Defective contact of connector (See Note 2) Disconnection in wiring harnees (See Note 3) (defective clamp) (external force applied) Defective sensor Clean Replace sensor (See Note 4) Clean connector or replace Replace sensor Replace FloatUP Max.1q FloatDOWN Min.1 Mq