STRUCTURE AND FUNCTION HYDRAULIC PUMP 2. When pump controller is abnormal and PC prolix switch in ON. a. When load on main pump is light. i. If there is a failure in the pump controller, turn PC prolix switch ON to switch to the resister side. In this case, the power source is taken directly from the battery. But if the current is used as it is, it is too large, so use the resister to control the current flowing to PC-EPC valve solenoid (1). ii. When this is done, the current becomes constant, so the force pushing piston (2) is also constant. iii.

If main pump pressures PP1 and PP2 are low, the combined force of the pump pressure and the force of PC-EPC valve solenoid (1) is weaker that the spring set force, so spool (3) is balanced at a position to the left. iv. At this point, port C is connected to the drain pressure of port D , and the large diameter end of the piston of servo piston (9) also becomes the drain pressure PT through the LS valve. When this happens, the pressure at the small diameter end of the piston is large, so servo piston (9) moves in the direction to make the discharge amount larger. 10-34