Komatsu — eebm001902 a3.pdf

STRUCTURE AND FUNCTION CLSS Unload valve Function When all the control valves are at neutral, the oil discharged when the pump is at the mini- mum swash plate angle is drained. When this happens, the pump pressure becomes a pres- sure that matches the set load of springs (11A, 11B) inside the valve ( P1 pressure). The LS pressure is drained form LS bypass valve, so LS pressure tank pressure 0 MPa (0 kg/ cm 2 ). Operation 1. The pressure in pump passages (7A, 7B) is re- ceived by the end face of valves (10, 10B). The control valve is at neutral, so the pressure in LS circuits (8A, 8B) is 0 MPa (0 kg/cm 2 ). 2. The pressurized oil in pump passages (7A, 7B) is stopped by valves (10A, 10B).

There is no way for the pressurized oil discharged by the pump to escape, so the pressure rises. When this pressure becomes larger than the force of springs (11A, 11B), valves (10A, 10B) move to the left, ports B and C are connectd and the pump pressure flows to tank passages (9A, 9B). In addition, the pressurized oil in LS cir- cuits (8A, 8B) passes from orifice A through port C , and is drained to tank passages (9A, 9B). Therefore, when the valve is actuated, LS pressure tank pressure. 3.

When the unload operation is carried out, the differential pressure (pump discharge pressure - LS circuit pressure) is greater than the pump LS control pressure, so a signal is sent to move the pump swash plate to the minimum angle. 10-54