STRUCTURE AND FUNCTION CLSS Pump merge-divider valve 1. Main spool 2. Spring 3. LS spool 4. Spring 5. LS circuit (bucket end) 6. LS circuit (arm end) 7. LS circuit (arm end) 8. LS circuit (bucket end) Operation 1. When merging pump flow (when pilot pressure PS is OFF) a. Pilot pressure PS is OFF, so main spool (1) is pushed to the left by spring (2), and ports E and F are interconnected. Therefore, pressurized oil P1 and P2 discharged from the two pumps is merged at ports E and F , and is sent to the control valve that de- mands the oil. b. In the same way, LS spool (3) is also pushed to the left by spring (4), so the ports are connected as follows. Connected ports: A Ј D , B Ј C c.
Therefore, the LS pressure supplied from the spols of each control valve to LS cir- cuits (5), (6), (7), and (8) are all sent to the pressure compensation valve and the other valve. Function This acts to merge or divide (send to its own control valve group) oil flows P1 and P2 of pres- surized oil discharged from the two pumps. At the same time, it also carries out merging and dividing of the LS circuit pressure. 10-68