Komatsu — EVERY 1000 HOURS MAINTENANCE

. MAINTENANCE MAINTENANCE PROCEDURE CHANGE OIL IN SWING MACHINERY CASE WARNING 4 - 65 EVERY 1000 HOURS Carry out the periodic mai ntenance work of every 100, 2 50 and 500 hours o f operation at th The parts and oil are at high t emperature after the engine is sto pped, and may cause serious burns. Wa it for the temperature to go d own before starting the o R efill capacity: 2.5 liters 1. Swing the upper struct ure so that drain plug (P) is be tween the left and right tracks. der drain valve (P) at the bottom of the 2. Set an oil container un machine. 3.

Remove drain plug (P) at the bottom of the machine, drain the oil, then tighten the dr Tightening torque for oil, then tighten the dr ain plug again. drain plug: 44.1 to 93.1 Nm (4.5 to 9.5 kgm, 32.5 to 68.7 lbft) Tightening torque for kgm, 32.5 to 68.7 l 4. Remove dipstick (G), t hen add the specified amount of oil from oil filler (F). dipstick with a cloth. ) into filler pipe, then remove it. 5. Wipe off the oil on the 6. Fully insert dipstick (G ) into filler pipe, then remove i 7. The oil level should be between the H and L marks o n oil level gauge (G). If the oil le oil filler port (F).

If the oil is above the vel is below the L mark, add oil through H mark, drain the excess oil from drain e oil level again. 8. plug (P), then check th