ADJUSTING THE PUMP FLOW NOTE: For further information, see "Flow Control" on page 2-43. 1. On the instrument panel, press the flow control button , the flow control screen (Figure 86) will be displayed. 2. Use "UP" ( ) or "DOWN" ( ) buttons to adjust flow rate. 3. Press "SELECT" ( ) button, to return to normal display screen and save the flow rate setting. FLOW CONTROL C H E F C H 1 2 3 4 5 6 7 8 0 9 ESC: CANCEL : APPLY Figure 86 FG013831 DX140R/DX140LCR Operation 3-38 Setting Flow Rate (l/min) 0 48.5 1 57 2 66 3 69 4 78.5 5 90 6 96.5 7 106.5 8 108 9 114 10 114