Doosan DX140R/DX140LCR — Inspect Bucket Teeth and Side Cutters for Signs of Wear

NOTE: When refill or replace coolant, select "heater-full hot" mode to fully open the water valve. Coolant will then flow into the heater's core to prevent air from being trapped in it. EX1502246 Figure 31 Check Level of Window Washer Liquid 1. Open left rear access door and check fluid level in windshield washer tank. 2. Open fill cap and add fluid. NOTE: Use a washer liquid that is rated for all seasons. This will prevent freezing during cold weather operation. FG014424 Figure 32 Inspect Bucket Teeth and Side Cutters for Signs of Wear 1. On a daily basis, inspect the bucket teeth to make sure that tooth wear or breakage has not developed. 2.

Do not allow the replaceable bucket teeth to wear down to the point that bucket adapter is exposed. See Figure 33. NOTE: These instructions are only for DOOSAN OEM buckets. If you are using other manufacturers' buckets, refer to their specific instructions. Figure 33 Inspection, Maintenance and Adjustment 4-23 DX140R/DX140LCR Reference Number Description 1 Point 2 Adapter 3 Pin