Change Breaker Filter (Optional) WARNING AVOID DEATH OR SERIOUS INJURY The hydraulic oil will be hot after normal machine operation. Allow the system to cool down before changing pilot filter. Figure 51 1. Park machine on firm and level ground. Lower the front attachment to the ground and stop engine. 2. Loosen the hydraulic oil tank breather cap to release pressure. 3. Locate breaker filter assembly (Figure 51). 4. Position a container under the filter assembly. Remove drain plug and completely drain the assembly. 5. Using a 30 mm spanner, unscrew filter housing from filter bottom. 6. Remove O-ring from filter head. 7. Replace filter. 8.
Apply a small amount of oil around the entire O-ring and install the filter housing on the filter head. 9. Install drain plug in bottom of filter housing. NOTE: Tightening torque: 27 kg•m (265 Nm, 195 ft lb) 10. After changing breaker filter, vent air from pump and check level of hydraulic oil tank. Inspection, Maintenance and Adjustment 4-35 DX140R/DX140LCR FG014429 FG014429