DX140R/DX140LCR Inspection, Maintenance and Adjustment 4-40 2. Open the cover by the removing knobs (Figure 58). FG01451 Figure 58 3. Remove filter (Figure 59) and inspect for any damage. 4. Use compressed air to clean filter. If filter is still dirty, then change to new one. 5. Reassemble filter and cover in reverse order. FG01451 Figure 59 Check and Clean Air-Conditioning Inner Filter WARNING AVOID DEATH OR SERIOUS INJURY All service and inspection of air-conditioning system must be performed with the starter switch in the "O" (OFF) 1 FG01505 position. Figure 60 WARNING AVOID DEATH OR SERIOUS INJURY If using compressed air to clean the element, make sure that proper eye protection is worn.
1. Open the cover by removing knobs (1, Figure 60). 2. Remove screw (2, Figure 61) and filter (3, Figure 61) from the cover. FG01451 FG01451