5. Clean the outer filter (4, Figure 67) by blowing compressed air from the inside of the filter towards the outside. Do not use more than 205 kPa (30 psi) air pressure. HAOC570L Figure 68 6. Check outer filter by shinning a light through it. If small holes or thinner parts are found on the element after cleaning it, replace the filter. 7. Clean the inside of the air cleaner body and the inside of the air cleaner cover. Do not use compressed air. 8. Properly install the air filter and cover. 9. After filter service be sure to install cover with arrows pointing "UP". NOTE: If after cleaning the outer filter, the air cleaner clogged indicator remains "ON", replace the outer and inner filters.
Do not clean inner filter. FG000412 Figure 69 Inspection, Maintenance and Adjustment 4-43 DX140R/DX140LCR