Doosan DX140R/DX140LCR — Replace Outer and Inner Air Cleaner Elements

2,000 HOUR / YEARLY SERVICE Perform All Daily, 50, 250, 500 and 1,000 Hour Service Checks Replace Outer and Inner Air Cleaner Elements WARNING AVOID DEATH OR SERIOUS INJURY Never clean or attempt to remove the air cleaner element if the engine is running. PWR FG013734 Figure 101 NOTE: Replace outer element after cleaning 5 times or every 2,000 hours of service. NOTE: Replace inner element whenever a new outer element is installed. If there is clogged filter signal on the gauge panel, use the following procedure. 1. Open the access door at the rear of the cabin. 2. Remove the evacuator valve (1, Figure 102) and air cleaner cover (2). NOTE: Inspect evacuator valve seal lips for wear or damage.

Replace valve if necessary. Install evacuator valve with lips parallel to the cover. Figure 102 FG014432 3. Remove outer filter (4, Figure 102) from the air cleaner housing. 4. Clean the air cleaner cover and the inside of the air cleaner housing. 4 5 5. Remove inner filter (5, Figure 103). 2 6. Clean out inside of air cleaner housing. Do not use compressed air to blow out housing. 7. Install new inner filter. Do not clean and reuse inner element. 8. Install new outer filter. 9. Install air cleaner cover and evacuator valve. NOTE: Make sure that all gaskets and cover are properly installed and seated. 3 Figure 103 1 FG003466 Inspection, Maintenance and Adjustment 4-57 DX140R/DX140LCR