Doosan DX140R/DX140LCR — General Venting

DX140R/DX140LCR Inspection, Maintenance and Adjustment 4-82 Swing Motor IMPORTANT If the air is not vented from the system, it will cause damage to the swing motor and bearings. NOTE: Perform this only when oil has been drained from swing motor. FG009596 1. Stop engine. Figure 131 2. Disconnect drain hose and fill swing motor case with hydraulic oil. 3. Connect the drain hose. 4. Start engine and set throttle at "LOW IDLE" and swing upper structure slowly two full revolutions to the left and right. Travel Motor NOTE: Perform this only when oil is drained from travel motor 1. Stop engine 2. Disconnect drain hose (Figure 132) and fill motor case with hydraulic oil. 3. Connect drain hose. 4.

Start engine and set engine speed control dial to "LOW FG009597 IDLE". Run the engine for one minute and slowly drive Figure 132 excavator forwards and backwards. General Venting 1. After venting air from all components, stop engine and check the hydraulic oil level. Fill hydraulic oil tank to "H" mark on sight gauge. 2. Start engine and operate all controls again, run engine for five minutes to ensure all systems have been vent and purged of air. Move engine speed to "LOW IDLE", and check hydraulic oil level again. Add oil as necessary. 3. Check for oil leaks and clean all fill and venting locations. FG009596